SG1041CD/BNC - pH Electrode, Glass, Research Grade

SG1041CD/BNC - pH Electrode, Glass, Research Grade

SG1041CD/BNC
In laboratory environments such as medical, biological, and materials science research groups, samples and test conditions are constantly changing, but accuracy is always critical. The SG1041CD/BNC is a highly versatile combination pH electrode, specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals allow testing of low ionic samples. Safely measure samples containing heavy metals, TRIS buffer, or proteins thanks to the double junction reference design, which prevents fouling. Even test highly reactive chemicals: with a glass body, the SG1041CD/BNC is inert to a wide range of chemical reactions. High accuracy, temperature responsive measurements (pH 0-14) Chemically inert glass body Double junction reference prevents contamination
Out of stock
€561
VAT included
Quantity

Out-of-Stock

In laboratory environments such as medical, biological, and materials science research groups, samples and test conditions are constantly changing, but accuracy is always critical. The SG1041CD/BNC is a highly versatile glass combination pH electrode, specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals allow testing of low ionic samples. Safely measure samples containing heavy metals, TRIS buffer, or proteins thanks to the double junction reference design, which prevents fouling. Even test highly reactive chemicals: with a glass body, the SG1041CD/BNC is inert to a wide range of chemical reactions. Sensorex RapidRenew reference design flushes away contaminants that might build up and slow response.

  • Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
  • Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
  • Safe for use with reactive chemicals: Glass bodies are inert to many chemical reactions
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • Ready for wet or corrosive environments: BNC protects meter connection

Recommended for: Low ionic samples, medical and pharmaceutical research, biological samples (including TRIS buffer), samples containing heavy metals

CA ResidentsProp 65 WARNING(S)

For optimal shelf life, store sensors at 15-30°C.

Direct replacement for pH3400.




Weight0.22 lbs
Dimensions8.25 × 2.25 × 2.25 in

In laboratory environments such as medical, biological, and materials science research groups, samples and test conditions are constantly changing, but accuracy is always critical. The SG1041CD/BNC is a highly versatile combination pH electrode, specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals allow testing of low ionic samples. Safely measure samples containing heavy metals, TRIS buffer, or proteins thanks to the double junction reference design, which prevents fouling. Even test highly reactive chemicals: with a glass body, the SG1041CD/BNC is inert to a wide range of chemical reactions.

  • High accuracy, temperature responsive measurements (pH 0-14)
  • Chemically inert glass body
  • Double junction reference prevents contamination
  • Refillable pump junction helps users easily extend sensor lifetime
  • Reinforced meter connection allows use in wet and corrosive environments

 

 

: SG1041CD/BNC
Out of stock

Data sheet

Dimensions
8.25 x 2.25 x 2.25 in
Applications
Glass Body pH Electrodes, Lab Sensors, Laboratory & Analytical, pH
Weight
0.22 lbs