SD7420CD-ORP - Sonde ORP différentielle avec sortie directe 4-20mA
   

SD7420CD-ORP - Sonde ORP différentielle avec sortie 4-20 mA directe

SD7420CD-ORP
Conçue pour les processus d'épuration des eaux, la sonde ORP SD7420CD-ORP résiste à l'encrassement grâce à sa référence remplaçable et à sa conception différentielle à trois électrodes, prolongeant la durée de vie. Sortie 4-20 mA directe pour une intégration simple sans transmetteur ni contrôleur.
Dépêchez-vous ! seulement 100 encore articles en stock.
1 377 €
TTC
Quantité

When an ORP sensor is constantly measuring a wastewater treatment process, it will be exposed to chemicals, suspended solids, and other contaminants. These contaminants can cause fouling of the ORP sensor reference, leading to sensor failure. Differential ORP sensors utilize three electrodes instead of the conventional two. This special design allows the sensor reference (salt bridge) and buffered electrolyte solution to be replaced, which extends working lifetime. Our SD7420CD features differential sensor technology with a direct 4-20mA output, so it can be integrated into control systems without the use of a transmitter or controller.

  • Reliable measurement performance: True differential measurement technology using solution ground
  • High accuracy measurements: Differential measurement technique virtually eliminates ground loop measurement error
  • No transmitter or controller required: Direct 4-20mA output for simple integration
  • Resists aggressive chemicals: Constructed of durable Ryton® Polyphenylene Sulfide (PPS)
  • Two year limited warranty: We stand behind our products with the Sensorex Guarantee

CA ResidentsProp 65 WARNING(S)

For optimal shelf life, store sensors at 15-30°C.



  • Measurement Range: -2000mV to +2000mV

    Temperature Range: 0-100⁰ C

    Pressure Range: 0 – 100 PSIG @ 40⁰ C (PVC fitting); 0 – 100 PSIG @ 60⁰ C (CPVC fitting); 0 – 100 PSIG @ 100⁰ C (stainless steel fitting);

    Body Construction: Ryton Polyphenylene Sulfide (PPS)

    Temperature Compensation: 300Ω NTC

    Connector: Tinned Leads

    Cable Length: 20 feet (6 meters)

    Power Supply (not included): 12 to 30 V DC (>24 V DC recommended)

    Installation: 1 1/2″ NPT

    Warranty: Two year limited warranty



Weight1.90 lbs
Dimensions10 × 4 × 3 in

When an ORP sensor is constantly measuring a wastewater treatment process, it will be exposed to chemicals, suspended solids, and other contaminants. These contaminants can cause fouling of the ORP sensor reference, leading to sensor failure. Differential ORP sensors utilize three electrodes instead of the conventional two. This special design allows the sensor reference (salt bridge) and buffered electrolyte solution to be replaced, which extends working lifetime. Our SD7420CD features differential sensor technology with a direct 4-20mA output, so it can be integrated into control systems without the use of a transmitter or controller.

  • True differential measurement technology using solution ground
  • Virtually zero ground loop measurement error
  • No transmitter or controller required
  • Constructed of durable Ryton® PPS
  • Two year limited warranty
: SD7420CD-ORP
: 100 Produits
Dépêchez-vous ! seulement 100 encore articles en stock.

Fiche technique

Dimensions
10 x 4 x 3 in
Applications
Traitement des eaux municipales et des eaux usées, capteurs en ligne, ORP
Plage de mesure
-2000mV à +2000mV
Garantie
Garantie limitée de deux ans
Plage de pression
0 - 100 PSIG à 40 °C (raccord en PVC); 0 - 100 PSIG à 60 °C (raccord en CPVC); 0 - 100 PSIG à 100 °C (raccord en acier inoxydable);
Construction de la carrosserie
Ryton polyphénylène sulfure (PPS)
Alimentation (non incluse)
12 à 30 V DC (>24 V DC recommandé)
Installation
1 1/2″ NPT
Longueur du câble
20 pieds (6 mètres)
Plage de température
0–100 °C
Compensation de la température
300Ω NTC
Connecteur
Fils étamés
Poids
1.90 lbs