S350CD/BNC - pH Electrode, Flat Tip

S350CD/BNC - pH Electrode, Flat Tip

S350CD/BNC
Agar plates, skin, and electrophoresis gels are all surfaces that may be difficult to measure with a typical glass bulb electrode due to concerns about bulb breakage. To facilitate these and other surface measurements, we created the S350CD/BNC flat tip pH electrode. It has a rugged flat measurement surface, which breaks less easily when it comes in contact with hard materials. This makes it a great choice for measuring slurries, sludges, and viscous samples as well as those containing suspended solids. Flat measurement tip for surface measurements and slurries Double junction electrode design prevents reference contamination Durable Ultem® body BNC protects meter connection One year limited warranty
En rupture de stock
6 116 Kč
TTC
Quantité

Rupture de stock

Agar plates, skin, and electrophoresis gels are all surfaces that may be difficult to measure with a typical pH glass bulb due to concerns about breakage. To facilitate these and other surface measurements, we created the S350CD/BNC flat tip pH electrode. It has a rugged flat measurement surface, which breaks less easily when it comes in contact with hard materials. This makes it a great choice for measuring slurries, sludges, and viscous samples as well as those containing suspended solids.

  • Ideal for surface measurements and slurries: rugged flat measurement tip resists breakage
  • Great for testing unknown sample types: double junction electrode reference design prevents contamination
  • Durable and Versatile: Ultem® body offers enhanced chemical compatibility and BNC protects meter connection
  • No maintenance required: sealed gel filled reference design
  • One year limited warrantyWe stand by our products with the Sensorex guarantee

CA ResidentsProp 65 WARNING(S)

For optimal shelf life, store sensors at 15-30°C.

Direct replacement for pH2100.



  • Measurement Range: 0-14 pH (low NA+ ion error)

    Response Time: 95% in 5 seconds

    Isopotential: 7.00 pH

    Offset: 0.2%

    Span: > 97%

    Connector: BNC

    Cable Length: Standard: 3 ft (1 m) or Custom (Please inquire)

    Warranty: One year limited warranty

    Diameter: 12mm

    Length: 150mm

    Reference: Sealed

    Junction Number: Double (2)

    Junction Material: HDPE and Pellon

    Reference Solution: 3.5 M KCl/AgCl/KNO3 (gel)

    Glass Shape: Flat

    Body Material: Ultem

    Temperature Range: 0-80° C

    Strain Relief: No

    BNC: Yes



Weight0.22 lbs
Dimensions8.25 × 2.25 × 2.25 in

Agar plates, skin, and electrophoresis gels are all surfaces that may be difficult to measure with a typical glass bulb electrode due to concerns about bulb breakage. To facilitate these and other surface measurements, we created the S350CD/BNC flat tip pH electrode. It has a rugged flat measurement surface, which breaks less easily when it comes in contact with hard materials. This makes it a great choice for measuring slurries, sludges, and viscous samples as well as those containing suspended solids.

  • Flat measurement tip for surface measurements and slurries
  • Double junction electrode design prevents reference contamination
  • Durable Ultem® body
  • BNC protects meter connection
  • One year limited warranty
: S350CD/BNC
En rupture de stock

Fiche technique

Glass Shape
Flat
Isopotential
7.00 pH
Offset
0.2%
Warranty
One year limited warranty
Standard
3 ft (1 m) or Custom (Please inquire)
Junction Number
Double (2)
Strain Relief
No
BNC
Yes
Dimensions
8.25 x 2.25 x 2.25 in
Applications
Lab Sensors, Laboratory & Analytical, pH, Plastic Body pH electrodes
Junction Material
HDPE and Pellon
Measurement Range
0-14 pH (low NA+ ion error)
Diametre
12mm
Réference
Sealed
Longueur
150mm
Body Material
Ultem
Temperature Range
0-80° C
Connector
BNC
Solution de reference
3.5 M KCl/AgCl/KNO3 (gel)
Poids
0.22 lbs
Étendue de mesure
> 97%
Temps de réponse
95% in 5 seconds