S675 - pH Sensor Kit, Hot Tap Insertion Assembly
  • Nuevo
S675 - pH Sensor Kit, Hot Tap Insertion Assembly
Users installing into large tanks, large process lines and scrubber lines will appreciate this hot tap assembly sensor kit. Adjustable insertion depth up to 12” ensures sensor is in flow for best results. Designed in CPVC for a user friendly cost compared to expensive stainless models, the S675 assembly is well suited for most water and wastewater treatment applications. Incorporates optional automatic temperature compensation (ATC) with 1000Ω RTD. Supplied with 10 foot cable. Kit also includes (1)  S656CD Flat Surface pH Cartridge . The  BV-1 Ball Valve  (sold separately) facilitates removal from system without need for shutdown. Durable CPVC design is suitable for most applications Remove sensors for cleaning and maintenance without system shutdown Easy installat
2.056 €
S8200-ORP - Modular In-line ORP Sensors
  • Nuevo
S8200-ORP - Modular In-line ORP Sensors
S8200-ORP – Modular In-line ORP Sensors The S8200-ORP is a self-cleaning ORP sensor that delivers the most reliable online monitoring in a unique, modular package that minimizes total cost of ownership.  Sensors can be changed in a few seconds with no tools or re-wiring required by swapping the S8000CD-ORP Quick Change Replacement Cartridge . Reliable performance in demanding applications Lightning fast sensor changes Perfect for pressurized applications Low total cost of ownership One year limited warranty Optional Accessories: Differential amplifier module for applications with ground loop issues Unity gain amplifier module  transmits sensor signal up to 1000ft
1.508 €
S272CD-ORP - ORP Sensor, Online Process
  • Nuevo
S272CD-ORP - ORP Sensor, Online Process
Moderately contaminated water, such as industrial source water or natural water resources, may contain chemicals and debris that damage ORP probe components. Continuous monitoring in these types of applications requires a durable and low maintenance ORP probe. Our S272 series of ORP probes feature a double junction design to protect the reference cell from contamination by sample components that interact with silver. The flat measurement surface is self-cleaning and resists breakage, for minimal maintenance. Reliable performance in demanding applications Extended sensor lifetime Versatile design for submersion or in-line mounting One year limited warranty
716 €
SD7000CD-ORP - Differential ORP Sensor, 5-Wire Online Process
  • Nuevo
SD7000CD-ORP - Differential ORP Sensor, 5-Wire Online Process
Our SD7000 differential ORP sensor offers unsurpassed ORP measurement accuracy by minimizing reference junction fouling and eliminating ground loops. The SD7000 series delivers greater reliability and less required maintenance than a conventional combination ORP sensor. Extended sensor lifetime can be achieved by replacing the sensor reference (salt bridge). Reliably measures ORP in environments with rapid temperature changes with built-in quick response automatic temperature compensation (ATC). Reliable measurement performance: True differential ORP measurement technology using solution ground Direct-fit Compatibility: Replacement sensor for several popular Hach® & Water Analytics® models Perfect for pressurized applications: Sealed, no maintenance reference design Built for difficult
1.182 €
SD7420CD-ORP - Differential ORP Probe with Direct 4-20mA Output
  • Nuevo
SD7420CD-ORP - Differential ORP Probe with Direct 4-20mA Output
When an ORP sensor is constantly measuring a wastewater treatment process, it will be exposed to chemicals, suspended solids, and other contaminants. These contaminants can cause fouling of the ORP sensor reference, leading to sensor failure. Differential ORP sensors utilize three electrodes instead of the conventional two. This special design allows the sensor reference ( salt bridge ) and buffered electrolyte solution to be replaced, which extends working lifetime. Our SD7420CD features differential sensor technology with a direct 4-20mA output, so it can be integrated into control systems without the use of a transmitter or controller. True differential measurement technology using solution ground Virtually zero ground loop measurement error No transmitter or controller r
1.377 €
SD7500CD-ORP - Differential ORP Probe, Universal
  • Nuevo
SD7500CD-ORP - Differential ORP Probe, Universal
Continuous online ORP monitoring in applications like metal finishing and chrome waste treatment wears down ORP sensors, leading to reference contamination. A differential ORP probe utilizes three electrodes instead of two, which extends the sensor’s working lifetime in challenging applications. Replacing the sensor reference ( salt bridge ) and buffered electrolyte solution can prevent sensor replacements, saving time and money. The SD7500CD-ORP is a self-powered differential ORP probe, allowing use with any conventional ORP transmitter. Differential measurement technology with solution ground Buffered electrolyte reference resists fouling Compatible with any conventional pH/ORP transmitter Replaceable double junction salt bridge Refillable reference solution Two Year limited Wa
1.261 €
CS650 - Conductivity Sensor, Stainless Steel
  • Nuevo
CS650 - Conductivity Sensor, Stainless Steel
General-Purpose Sensor for Use in a Variety of Applications Cooling Towers Demin Influent Robust Single-Body Design 1/2” NPT Stainless Steel Hexagonal body shape for ease of installation
1.229 €
S550C-ORP Heavy-Duty ORP Sensor
  • Nuevo
S550C-ORP Heavy-Duty ORP Sensor
Some of our laboratory ORP electrodes, including the S550C-ORP/BNC, have gotten an update! Looking for a polymer body, double junction ORP electrode for lab use? Check out the ORP2000 , which replaces the S550C-ORP in our new laboratory ORP electrode line. Want to know what else has changed? Download the Specification Sheet for Laboratory ORP Electrodes.
360 €