Our CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications. Reliable process control Lightning fast sensor calibration Perfect for use in all environments Compatible with a wide variety of sensors One year limited warranty Note: Transmitter is only compatible with sensors with tinned leads and either 30k NTC or Pt1000Ω RTD temperature compensation.
Select Outputs : 2x 4-20mA
Nicht auf Lager
1.608 €
Bruttopreis
Menge

Nicht auf Lager

Our CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications.

  • Reliable process control: Two (2) adjustable Hi/Lo relay contacts
  • Lightning fast sensor calibration: Preset standards make sensor calibration quick and simple
  • Perfect for use in all environments: LCD display with auto-sense backlight technology & NEMA 4X, IP65 enclosure
  • Compatible with a wide variety of sensors: For use with all Sensorex contacting conductivity sensors
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee

Note: CX2000 Conductivity Controller and 4-20mA transmitter is compatible with sensors with tinned lead connectors and either 30k NTC or Pt1000Ω RTD temperature compensation.

CA ResidentsProp 65 WARNING(S)



  • Measuring Range:

    • Conductivity: 0.000 uS/cm -200.0 mS/cm in 5 ranges, 0.01/.01/1 uS/cm, 0.01/0.1mS/cm resolution, +/-1% Accuracy (+/- 1 digit)
    • Resistivity 0.00-20.00 MΩ • cm, 0.01 MΩ • cm resolution, +/-1% Accuracy(+/- 1 digit)
    • Temperature Range: -30 °C to 130 °C, 0.1 °C resolution, 0.2 °C accuracy

    Calibration Mode: Automatic with built-in standard solutions manual cell constant adjustment
    Cell Constants: 0.01, 0.05, 0.1, 0.5, 10/cm fixed or freely selectable 0.0080 – 19.99/cm
    Analog Output 1: Isolated DC 0/4 -20mA, corresponding to conductivity or resistivity. Max load 500 Ω.
    Analog Output 2: Isolated DC 0/4 -20mA, corresponding to temperature output. Max load 500 Ω.
    Set-Points: Contact: 240V AC, 5A max
    Activate: setpoints Hi/Low, Hi/Hi, Low/Low, ON/OFF
    Enclosure: NEMA 4X IP65, with push-button control pad. HWD: 96 mm (3.77”) x 132 mm (5.20”), 1/4 DIN
    Panel Cut-Out: 93mm (3.66”) x 93mm (3.66”)
    Weight: approx. 0.50kg (1.1lb)
    Mounting Options: Panel or Wall Mount
    Ambient Temperature: 0 ° C to 50 ° C
    Storage Temperature: -10 ° C to 70 ° C
    Temperature Compensation: NTC 30K or Pt1000 RTD with automatic compensation or manual
    Temperature Coefficient: Linear comp 0.00-40.00%, Non-linear comp for natural waters
    Power Requirement: 100-240V AC +/- 10%, 5W max, 50/60 H



Weight2.40 lbs
Dimensions11 × 10.5 × 7 in
Select Outputs2x 4-20mA, 1x 4-20mA + 1x MODBUS

Our CX2000 is a fully-featured conductivity controller and 4-20mA transmitter for reading contacting conductivity sensors and programming process control. Set points are easily selected for 2 relay outputs and 1 wash control. Sensor calibration is simple with preset standards. The large LCD display features auto-sense back-light technology for use in all environments, including cooling tower controller applications.

  • Reliable process control
  • Lightning fast sensor calibration
  • Perfect for use in all environments
  • Compatible with a wide variety of sensors
  • One year limited warranty

Note: Transmitter is only compatible with sensors with tinned leads and either 30k NTC or Pt1000Ω RTD temperature compensation.

: CX2000 (Standard)
Nicht auf Lager

Technische Daten

Analog Output 2
Isolated DC 0/4 -20mA, corresponding to temperature output. Max load 500 Ω.
Contact
240V AC, 5A max
Mounting Options
Panel or wall mount
Temperature Coefficient
Linear comp 0.00-40.00%, Non-linear comp for natural waters
H WD
96 mm (3.77") x 132 mm (5.20"), 1/4 DIN
Activate
setpoints Hi/Low, Hi/Hi, Low/Low, ON/OFF
Ambient Temperature
0 ° C to 50 ° C
Storage Temperature
-10 ° C to 70 ° C
Dimensions
11 x 10.5 x 7 in
Applications
Conductivity, Controllers & Transmitters, Hydroponics & Agriculture
Power Requirement
100-240V AC +/- 10%, 5W max, 50/60 H
Cell Constants
0.01, 0.05, 0.1, 0.5, 10/cm fixed or freely selectable 0.0080 - 19.99/cm
Enclosure
NEMA 4X IP65, with push-button control pad.
Calibration Mode
Automatic with built-in standard solutions manual cell constant adjustment
Panel Cut-Out
93mm (3.66") x 93mm (3.66")
Analog Output 1
Isolated DC 0/4 -20mA, corresponding to conductivity or resistivity. Max load 500 Ω.
Temperature Compensation
NTC 30K or Pt1000 RTD with automatic compensation or manual
Select Outputs
2x 4-20mA, 1x 4-20mA + 1x MODBUS
Gewicht
2.40 lbs