DO6400 - Dissolved Oxygen Sensor with Digital Communication

DO6400 - Dissolved Oxygen Sensor with Digital Communication

DO6442/T-MB/20/TL/TL
Now Available with optional MODBUS/RS485 Interface Our DO6400 series of galvanic dissolved oxygen sensors deliver accurate measurements with very fast response time. Calibration is simple and only requires a single-point air calibration. Sensor directly outputs Millivolt, 4-20mA analog or MODBUS/RS485 digital signal scaled to the sensor range for easy PLC integration. Fast response time for accurate dissolved oxygen monitoring Direct MilliVolt, 4-20mA analog or MODBUS/RS485 digital output signal to integrate with a PLC or other control system Input Voltage Options: 12V DC – MODBUS only 24V DC – 4-20mA & MODBUS Ready for long-term deployment with large electrolyte reservoir One year limited warranty
Communication : Modbus
Range : 0 - 300%
Nicht auf Lager
2.206 €
Bruttopreis
Menge

Nicht auf Lager

Our DO6400 series galvanic dissolved oxygen sensor delivers accurate measurements with very fast response time. Calibration is simple and only requires a single-point air calibration, and its large electrolyte reservoir decreases downtime due to maintenance. This dissolved oxygen sensor directly outputs a Millivolt, 4-20mA analog or MODBUS/RS485 digital signal scaled to the sensor range for easy PLC integration.

  • Fast response time: Galvanic sensor technology delivers accurate dissolved oxygen monitoring
  • Simple system integration: Uses direct Millivolt, 4-20mA analog or MODBUS/RS485 digital output signal to integrate with a PLC or other control system
  • Input Voltage Options:
    • 12V DC – MODBUS only
    • 24V DC – 4-20mA & MODBUS
  • Infrequent, easy maintenance: Large electrolyte reservoir facilitates long-term sensor deployment
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee

CA ResidentsProp 65 WARNING(S)



  • Measurement Range: 0-100% (DO6441) or 0-200% (DO6442) dissolved oxygen

    Temperature Range: 0-50⁰ C

    Input Voltage Options:

    • 12V DC – MODBUS only
    • 24V DC – 4-20mA & MODBUS

    Body Construction: Noryl, PTFE,Viton®

    Power Requirement: 12-36V DC

    Cable Length: 10 feet (3 meters)

    Connector: Tinned leads

    Warranty: One year limited warranty



Weight1.68 lbs
Dimensions10.75 × 4.4 × 3.4 in
Range0-100%, 0 - 150%, 0-200%, 0 - 300%
Communication4 - 20 mA, Modbus, Millivolt

Now Available with optional MODBUS/RS485 Interface

Our DO6400 series of galvanic dissolved oxygen sensors deliver accurate measurements with very fast response time. Calibration is simple and only requires a single-point air calibration. Sensor directly outputs Millivolt, 4-20mA analog or MODBUS/RS485 digital signal scaled to the sensor range for easy PLC integration.

  • Fast response time for accurate dissolved oxygen monitoring
  • Direct MilliVolt, 4-20mA analog or MODBUS/RS485 digital output signal to integrate with a PLC or other control system
  • Input Voltage Options:
    • 12V DC – MODBUS only
    • 24V DC – 4-20mA & MODBUS
  • Ready for long-term deployment with large electrolyte reservoir
  • One year limited warranty
: DO6442/T-MB/20/TL/TL
Nicht auf Lager

Technische Daten

Body Construction
Noryl, PTFE,Viton®
Power Requirement
12-36V DC
Dimensions
10.75 x 4.4 x 3.4 in
Applications
Aquaculture & Aquarium, Dissolved Oxygen, Environmental, Online Sensors, Smart Sensors
Measurement Range
0-100% (DO6441) or 0-200% (DO6442) dissolved oxygen
Warranty
One year limited warranty
Kabellänge
10 feet (3 meters)
Temperature Range
0-50⁰ C
Connector
Tinned Leads
Range
0-100%, 0 - 150%, 0-200%, 0 - 300%
Communication
4 - 20 mA, Modbus, Millivolt
Gewicht